Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 111(21): 215001, 2013 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-24313493

RESUMO

Radiation-driven, low-adiabat, cryogenic DT layered plastic capsule implosions were carried out on the National Ignition Facility (NIF) to study the sensitivity of performance to peak power and drive duration. An implosion with extended drive and at reduced peak power of 350 TW achieved the highest compression with fuel areal density of ~1.3±0.1 g/cm2, representing a significant step from previously measured ~1.0 g/cm2 toward a goal of 1.5 g/cm2. Future experiments will focus on understanding and mitigating hydrodynamic instabilities and mix, and improving symmetry required to reach the threshold for thermonuclear ignition on NIF.

2.
Phys Rev Lett ; 111(8): 085004, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-24010449

RESUMO

Deuterium-tritium inertial confinement fusion implosion experiments on the National Ignition Facility have demonstrated yields ranging from 0.8 to 7×10(14), and record fuel areal densities of 0.7 to 1.3 g/cm2. These implosions use hohlraums irradiated with shaped laser pulses of 1.5-1.9 MJ energy. The laser peak power and duration at peak power were varied, as were the capsule ablator dopant concentrations and shell thicknesses. We quantify the level of hydrodynamic instability mix of the ablator into the hot spot from the measured elevated absolute x-ray emission of the hot spot. We observe that DT neutron yield and ion temperature decrease abruptly as the hot spot mix mass increases above several hundred ng. The comparison with radiation-hydrodynamic modeling indicates that low mode asymmetries and increased ablator surface perturbations may be responsible for the current performance.

3.
Phys Rev Lett ; 111(4): 045001, 2013 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-23931375

RESUMO

Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. Low neutron yields and hot-spot mix mass between 34(-13,+50) ng and 4000(-2970,+17 160) ng are observed.

4.
Rev Sci Instrum ; 83(10): 10E525, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127032

RESUMO

Hohlraums are employed at the national ignition facility to convert laser energy into a thermal x-radiation drive, which implodes a fusion capsule, thus compressing the fuel. The x-radiation drive is measured with a low spectral resolution, time-resolved x-ray spectrometer, which views the region around the hohlraum's laser entrance hole. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the size of the hohlraum's opening ("clear aperture") and fraction of the measured x-radiation, which comes from this opening, must be known. The size of the clear aperture is measured with the time integrated static x-ray imager (SXI). A soft x-ray imaging channel has been added to the SXI to measure the fraction of x-radiation emitted from inside the clear aperture. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the peak of the x-ray spectrum of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.

5.
Phys Rev Lett ; 108(21): 215005, 2012 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-23003274

RESUMO

The National Ignition Facility has been used to compress deuterium-tritium to an average areal density of ~1.0±0.1 g cm(-2), which is 67% of the ignition requirement. These conditions were obtained using 192 laser beams with total energy of 1-1.6 MJ and peak power up to 420 TW to create a hohlraum drive with a shaped power profile, peaking at a soft x-ray radiation temperature of 275-300 eV. This pulse delivered a series of shocks that compressed a capsule containing cryogenic deuterium-tritium to a radius of 25-35 µm. Neutron images of the implosion were used to estimate a fuel density of 500-800 g cm(-3).

6.
Phys Rev Lett ; 108(13): 135006, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22540711

RESUMO

We have imaged hard x-ray (>100 keV) bremsstrahlung emission from energetic electrons slowing in a plastic ablator shell during indirectly driven implosions at the National Ignition Facility. We measure 570 J in electrons with E>100 keV impinging on the fusion capsule under ignition drive conditions. This translates into an acceptable increase in the adiabat α, defined as the ratio of total deuterium-tritium fuel pressure to Fermi pressure, of 3.5%. The hard x-ray observables are consistent with detailed radiative-hydrodynamics simulations, including the sourcing and transport of these high energy electrons.

7.
Phys Rev Lett ; 106(8): 085003, 2011 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-21405579

RESUMO

The first soft x-ray radiation flux measurements from hohlraums using both a 96 and a 192 beam configuration at the National Ignition Facility have shown high x-ray conversion efficiencies of ∼85%-90%. These experiments employed gold vacuum hohlraums, 6.4 mm long and 3.55 mm in diameter, heated with laser energies between 150-635 kJ. The hohlraums reached radiation temperatures of up to 340 eV. These hohlraums for the first time reached coronal plasma conditions sufficient for two-electron processes and coronal heat conduction to be important for determining the radiation drive.

8.
Rev Sci Instrum ; 81(10): 10E321, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034019

RESUMO

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an ∼20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30±10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of ∼2×10(15) W/cm(2) for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1×10(14) W/cm(2) over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to ±5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30±10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

9.
Rev Sci Instrum ; 81(10): 10E538, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034065

RESUMO

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 µm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

10.
Science ; 327(5970): 1228-31, 2010 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-20110465

RESUMO

Indirect-drive hohlraum experiments at the National Ignition Facility have demonstrated symmetric capsule implosions at unprecedented laser drive energies of 0.7 megajoule. One hundred and ninety-two simultaneously fired laser beams heat ignition-emulate hohlraums to radiation temperatures of 3.3 million kelvin, compressing 1.8-millimeter-diameter capsules by the soft x-rays produced by the hohlraum. Self-generated plasma optics gratings on either end of the hohlraum tune the laser power distribution in the hohlraum, which produces a symmetric x-ray drive as inferred from the shape of the capsule self-emission. These experiments indicate that the conditions are suitable for compressing deuterium-tritium-filled capsules, with the goal of achieving burning fusion plasmas and energy gain in the laboratory.

11.
Front Mater Sci China ; 3(2): 163-168, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20865144

RESUMO

The majority of the mineral phase of the Lytechinus variegatus tooth is comprised of magnesium containing calcite crystal elements, collectively arranged so that they appear as a single crystal under polarized light, as well as under X-ray or electron irradiation. However, the crystal elements are small, and in spite of the common alignment of their crystal axes, are not the same size or shape in different parts of the tooth. The toughness of the tooth structure arises from the fact that it is a composite in which the crystals are coated with surface layers of organic matter that probably act to inhibit crack formation and elongation. In the growth region the organic components represent a greater part of the tooth structure. In the most heavily mineralized adoral region the primary plates fuse with inter-plate pillars. Using Scanning Electron Microscopy; TOF-SIMS mapping of the characteristic amino acids of the mineral related proteins; and isolation and characterization of the mineral-protected protein we report that the late-forming inter-plate pillars had more than a three-fold greater Mg content than the primary plates. Furthermore, the aspartic acid content of the mineral-related protein was highest in the high Mg pillars whereas the mineral-protected protein of the primary plates was richer in glutamic acid content.These results suggest that the Asp-rich protein(s) is important for formation of the late developing inter-plate pillars that fuse the primary plates and increase the stiffness of the most mature tooth segment. Supported by NIDCR Grant DE R01-01374 to AV.

12.
Appl Opt ; 47(19): 3494-9, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18594596

RESUMO

A single beamline of the National Ignition Facility (NIF) has been operated at a wavelength of 526.5 nm (2 omega) by frequency converting the fundamental 1053 nm (1 omega) wavelength with an 18.2 mm thick type-I potassium dihydrogen phosphate (KDP) second-harmonic generator (SHG) crystal. Second-harmonic energies of up to 17.9 kJ were measured at the final optics focal plane with a conversion efficiency of 82%. For a similarly configured 192-beam NIF, this scales to a total 2 omega energy of 3.4 MJ full NIF equivalent (FNE).

13.
Appl Opt ; 46(16): 3276-303, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17514286

RESUMO

The National Ignition Facility (NIF) is the world's largest laser system. It contains a 192 beam neodymium glass laser that is designed to deliver 1.8 MJ at 500 TW at 351 nm in order to achieve energy gain (ignition) in a deuterium-tritium nuclear fusion target. To meet this goal, laser design criteria include the ability to generate pulses of up to 1.8 MJ total energy, with peak power of 500 TW and temporal pulse shapes spanning 2 orders of magnitude at the third harmonic (351 nm or 3omega) of the laser wavelength. The focal-spot fluence distribution of these pulses is carefully controlled, through a combination of special optics in the 1omega (1053 nm) portion of the laser (continuous phase plates), smoothing by spectral dispersion, and the overlapping of multiple beams with orthogonal polarization (polarization smoothing). We report performance qualification tests of the first eight beams of the NIF laser. Measurements are reported at both 1omega and 3omega, both with and without focal-spot conditioning. When scaled to full 192 beam operation, these results demonstrate, to the best of our knowledge for the first time, that the NIF will meet its laser performance design criteria, and that the NIF can simultaneously meet the temporal pulse shaping, focal-spot conditioning, and peak power requirements for two candidate indirect drive ignition designs.

14.
Phys Rev Lett ; 95(21): 215004, 2005 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-16384150

RESUMO

The first hohlraum experiments on the National Ignition Facility (NIF) using the initial four laser beams tested radiation temperature limits imposed by plasma filling. For a variety of hohlraum sizes and pulse lengths, the measured x-ray flux shows signatures of filling that coincide with hard x-ray emission from plasma streaming out of the hohlraum. These observations agree with hydrodynamic simulations and with an analytical model that includes hydrodynamic and coronal radiative losses. The modeling predicts radiation temperature limits with full NIF (1.8 MJ), greater, and of longer duration than required for ignition hohlraums.

15.
Phys Rev Lett ; 94(9): 095005, 2005 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-15783974

RESUMO

The first hydrodynamic experiments were performed on the National Ignition Facility. A supersonic jet was formed via the interaction of a laser driven shock ( approximately 40 Mbar) with 2D and 3D density perturbations. The temporal evolution of the jet's spatial scales and ejected mass were measured with point-projection x-ray radiography. Measurements of the large-scale features and mass are in good agreement with 2D and 3D numerical simulations. These experiments provide quantitative data on the evolution of 3D supersonic jets and provide insight into their 3D behavior.

16.
Appl Opt ; 40(4): 447-51, 2001 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18357017

RESUMO

We describe the advantages of using diffractive (Fresnel) lenses on thin membranes over conventional optics for, among others, future space telescope projects. Fabrication methods are presented for lenses on two types of freestanding membrane up to 50 cm in size. The first is a Fresnel lens etched into a thin (380-microm) glass sheet, and the second is an approximately 50-microm-thick polymer membrane containing a Fresnel lens made by replication process from a specially made fused-silica master. We show optical performance analysis of all the lenses that are fabricated, including a diffraction-limited Airy spot from a 20-m- focal-length membrane lens in a diffractive telescope system.

17.
J Stroke Cerebrovasc Dis ; 10(4): 187-90, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-17903824

RESUMO

BACKGROUND: Early treatment with intra-arterial thrombolysis has been shown to be effective in the treatment of acute ischemic stroke because of occlusion of the middle cerebral artery. It is unclear how to use this therapy, however, when there is also occlusion of the parent internal carotid artery. CASE REPORT: A 43-year-old woman presented within 15 minutes of symptom onset caused by a large right anterior circulation ischemic stroke. Computed tomography scan showed a hyperdense right middle cerebral artery sign. Carotid angiography showed occlusion of the right internal carotid artery just distal to its origin. After balloon angioplasty of the internal carotid artery, the occluded right middle cerebral artery was successfully recanalized using intra-arterial tissue plasminogen activator. The patient had dramatic clinical improvement after the procedure, with almost complete resolution of her deficits. CONCLUSION: Acute middle cerebral artery thrombosis is occasionally associated with acute thrombotic occlusion of the parent internal carotid artery. In this situation, carotid occlusion may be treated first with percutaneous transluminal balloon angioplasty. Intra-arterial thrombolysis may then be applied directly to the site of middle cerebral artery thrombosis, improving chances for overall recanalization and excellent clinical response.

18.
J Endod ; 26(3): 133-7, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11199704

RESUMO

This study investigated the use of alendronate in the formation of new dentin in vitro. Extracted human premolar and molar teeth with immature apices were grown in tissue culture medium for 60 days. Six control specimens were grown without alendronate in the medium, and 22 experimental specimens were grown with alendronate at [10(-9) M] in the medium. Newly formed dentin was stained with tetracycline and procion brilliant red at days 1 to 3, 30 to 33, and 60. Specimens were decalcified and 5-micron sections were prepared for examination using fluorescent microscopy. New dentin formation was measured in microns at the most apical region, at 125-micron from the apical measurement and at 250-micron from the apical measurement. The alendronate group had 57.15% more growth than the control group at the most apical region, and this difference was significant (p = 0.0001). The results indicate that alendronate at [10(-9) M] is effective in accelerating dentin formation in vitro.


Assuntos
Alendronato/farmacologia , Dentina/efeitos dos fármacos , Dentinogênese/efeitos dos fármacos , Triazinas , Dente Pré-Molar , Corantes , Meios de Cultura , Técnicas de Cultura , Técnica de Descalcificação , Dentina/crescimento & desenvolvimento , Dentina/ultraestrutura , Corantes Fluorescentes , Humanos , Microscopia de Fluorescência , Dente Molar , Estatística como Assunto , Tetraciclina , Fatores de Tempo , Raiz Dentária/efeitos dos fármacos , Raiz Dentária/ultraestrutura
19.
Opt Lett ; 25(1): 1-3, 2000 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-18059762

RESUMO

A diffractive Alvarez lens is demonstrated that consists of two separate phase plates, each having complementary 16-level surface-relief profiles that contain cubic phase delays. Translation of these two components in the plane of the phase plates is shown to produce a variable astigmatic focus. Both spherical and cylindrical phase profiles are demonstrated with good accuracy, and the discrete surface-relief features are shown to cause less than lambda/10 wave-front aberration in the transmitted wave front over a 40 mm x 80 mm region.

20.
J Assoc Physicians India ; 47(8): 784-6, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10778622

RESUMO

BACKGROUND: Selegiline hydrochloride, a selective MAO-B inhibitor is known to improve motor functions in Parkinson's disease (PD). The present study was undertaken to study the effect of selegiline on memory and intelligence of PD patients. MATERIAL AND METHOD: Thirty two patients of PD were divided in two groups: selegiline group (n = 17) received 10 mg selegiline per day and control group (n = 15) did not receive selegiline. Patients receiving trihexyphenidyl and selegiline were excluded. All other treatment remained unchanged. All patients were examined at baseline and after three months for change in UPDRS score, WAIS score, memory test and P300. RESULTS: Patients in selegiline group had less severe disease (UPDRS score 24.11 +/- 14.07) as compared to controls (UPDRS score 40.53 +/- 18.52). There was significant improvement in UPDRS score (p < 0.05), WAIS (p < 0.001) and memory (p < 0.001) in selegiline group. In the control group there was a significant prolongation of P300 latency (p < 0.05). CONCLUSION: The study suggests that selegiline improves memory functions and intelligence in PD patients in addition to motor functions. It also prevents prolongation of P300 latency which is a marker of cognitive function.


Assuntos
Antiparkinsonianos/uso terapêutico , Inteligência/efeitos dos fármacos , Rememoração Mental/efeitos dos fármacos , Doença de Parkinson/tratamento farmacológico , Selegilina/uso terapêutico , Adulto , Antiparkinsonianos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Doença de Parkinson/psicologia , Selegilina/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...